#!/usr/bin/python
# -*- coding: UTF-8 -*-
#
# Script for checking global health of host running VMware ESX/ESXi
#
# Licence : GNU General Public Licence (GPL) http://www.gnu.org/
# This program is free software; you can redistribute it and/or
# modify it under the terms of the GNU General Public License
# as published by the Free Software Foundation; either version 2
# of the License, or (at your option) any later version.
#
# This program is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with this program; if not, write to the Free Software
# Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA
# 02110-1301, USA.
#
# Pre-req : pywbem
#
# Copyright (c) 2008 David Ligeret
# Copyright (c) 2009 Joshua Daniel Franklin
# Copyright (c) 2010 Branden Schneider
# Copyright (c) 2010-2016 Claudio Kuenzler
# Copyright (c) 2010 Samir Ibradzic
# Copyright (c) 2010 Aaron Rogers
# Copyright (c) 2011 Ludovic Hutin
# Copyright (c) 2011 Carsten Schoene
# Copyright (c) 2011-2012 Phil Randal
# Copyright (c) 2011 Fredrik Aslund
# Copyright (c) 2011 Bertrand Jomin
# Copyright (c) 2011 Ian Chard
# Copyright (c) 2012 Craig Hart
# Copyright (c) 2013 Carl R. Friend
# Copyright (c) 2015 Andreas Gottwald
# Copyright (c) 2015 Stanislav German-Evtushenko
# Copyright (c) 2015 Stefan Roos
#
# The VMware 4.1 CIM API is documented here:
# http://www.vmware.com/support/developer/cim-sdk/4.1/smash/cim_smash_410_prog.pdf
# http://www.vmware.com/support/developer/cim-sdk/smash/u2/ga/apirefdoc/
#
# The VMware 5.x CIM API is documented here:
# http://pubs.vmware.com/vsphere-50/index.jsp?nav=/5_1_1
#
# This Nagios plugin is maintained here:
# http://www.claudiokuenzler.com/nagios-plugins/check_esxi_hardware.php
#
#@---------------------------------------------------
#@ History
#@---------------------------------------------------
#@ Date : 20080820
#@ Author : David Ligeret
#@ Reason : Initial release
#@---------------------------------------------------
#@ Date : 20080821
#@ Author : David Ligeret
#@ Reason : Add verbose mode
#@---------------------------------------------------
#@ Date : 20090219
#@ Author : Joshua Daniel Franklin
#@ Reason : Add try/except to catch AuthError and CIMError
#@---------------------------------------------------
#@ Date : 20100202
#@ Author : Branden Schneider
#@ Reason : Added HP Support (HealthState)
#@---------------------------------------------------
#@ Date : 20100512
#@ Author : Claudio Kuenzler www.claudiokuenzler.com
#@ Reason : Combined different versions (Joshua and Branden)
#@ Reason : Added hardware type switch (dell or hp)
#@---------------------------------------------------
#@ Date : 20100626/28
#@ Author : Samir Ibradzic www.brastel.com
#@ Reason : Added basic server info
#@ Reason : Wanted to have server name, serial number & bios version at output
#@ Reason : Set default return status to Unknown
#@---------------------------------------------------
#@ Date : 20100702
#@ Author : Aaron Rogers www.cloudmark.com
#@ Reason : GlobalStatus was incorrectly getting (re)set to OK with every CIM element check
#@---------------------------------------------------
#@ Date : 20100705
#@ Author : Claudio Kuenzler www.claudiokuenzler.com
#@ Reason : Due to change 20100702 all Dell servers would return UNKNOWN instead of OK...
#@ Reason : ... so added Aaron's logic at the end of the Dell checks as well
#@---------------------------------------------------
#@ Date : 20101028
#@ Author : Claudio Kuenzler www.claudiokuenzler.com
#@ Reason : Changed text in Usage and Example so people dont forget to use https://
#@---------------------------------------------------
#@ Date : 20110110
#@ Author : Ludovic Hutin (Idea and Coding) / Claudio Kuenzler (Bugfix)
#@ Reason : If Dell Blade Servers are used, Serial Number of Chassis was returned
#@---------------------------------------------------
#@ Date : 20110207
#@ Author : Carsten Schoene carsten.schoene.cc
#@ Reason : Bugfix for Intel systems (in this case Intel SE7520) - use 'intel' as system type
#@---------------------------------------------------
#@ Date : 20110215
#@ Author : Ludovic Hutin
#@ Reason : Plugin now catches Socket Error (Timeout Error) and added a timeout parameter
#@---------------------------------------------------
#@ Date : 20110217/18
#@ Author : Ludovic Hutin / Tom Murphy
#@ Reason : Bugfix in Socket Error if clause
#@---------------------------------------------------
#@ Date : 20110221
#@ Author : Claudio Kuenzler www.claudiokuenzler.com
#@ Reason : Remove recently added Timeout due to incompabatility on Windows
#@ Reason : and changed name of plugin to check_esxi_hardware
#@---------------------------------------------------
#@ Date : 20110426
#@ Author : Claudio Kuenzler www.claudiokuenzler.com
#@ Reason : Added 'ibm' hardware type (compatible to Dell output). Tested by Keith Erekson.
#@---------------------------------------------------
#@ Date : 20110426
#@ Author : Phil Randal
#@ Reason : URLise Dell model and tag numbers (as in check_openmanage)
#@ Reason : Return performance data (as in check_openmanage, using similar names where possible)
#@ Reason : Minor code tidyup - use elementName instead of instance['ElementName']
#@---------------------------------------------------
#@ Date : 20110428
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : If hardware type is specified as 'auto' try to autodetect vendor
#@ Reason : Return performance data for some HP models
#@ Reason : Indent 'verbose' output to make it easier to read
#@ Reason : Use OptionParser to give better parameter parsing (retaining compatability with original)
#@---------------------------------------------------
#@ Date : 20110503
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Fix bug in HP Virtual Fan percentage output
#@ Reason : Slight code reorganisation
#@ Reason : Sort performance data
#@ Reason : Fix formatting of current output
#@---------------------------------------------------
#@ Date : 20110504
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Minor code changes and documentation improvements
#@ Reason : Remove redundant mismatched ' character in performance data output
#@ Reason : Output non-integral values for all sensors to fix problem seen with system board voltage sensors
#@ on an IBM server (thanks to Attilio Drei for the sample output)
#@---------------------------------------------------
#@ Date : 20110505
#@ Author : Fredrik Aslund
#@ Reason : Added possibility to use first line of a file as password (file:)
#@---------------------------------------------------
#@ Date : 20110505
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Simplfy 'verboseoutput' to use 'verbose' as global variable instead of as parameter
#@ Reason : Don't look at performance data from CIM_NumericSensor if we're not using it
#@ Reason : Add --no-power, --no-volts, --no-current, --no-temp, and --no-fan options
#@---------------------------------------------------
#@ Date : 20110506
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Reinstate timeouts with --timeout parameter (but not on Windows)
#@ Reason : Allow file:passwordfile in old-style arguments too
#@---------------------------------------------------
#@ Date : 20110507
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : On error, include numeric sensor value in output
#@---------------------------------------------------
#@ Date : 20110520
#@ Author : Bertrand Jomin
#@ Reason : Plugin had problems to handle some S/N from IBM Blade Servers
#@---------------------------------------------------
#@ Date : 20110614
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Rewrote file handling and file can now be used for user AND password
#@---------------------------------------------------
#@ Date : 20111003
#@ Author : Ian Chard (ian@chard.org)
#@ Reason : Allow a list of unwanted elements to be specified, which is useful
#@ in cases where hardware isn't well supported by ESXi
#@---------------------------------------------------
#@ Date : 20120402
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Making plugin GPL compatible (Copyright) and preparing for OpenBSD port
#@---------------------------------------------------
#@ Date : 20120405
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Fix lookup of warranty info for Dell
#@---------------------------------------------------
#@ Date : 20120501
#@ Author : Craig Hart
#@ Reason : Bugfix in manufacturer discovery when cim entry not found or empty
#@---------------------------------------------------
#@ Date : 20121027
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Added workaround for Dell PE x620 where "System Board 1 Riser Config Err 0: Connected"
#@ element outputs wrong return code. Dell, please fix that.
#@ Added web-link to VMware CIM API 5.x at top of script.
#@---------------------------------------------------
#@ Date : 20130424
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Another workaround for Dell systems "System Board 1 LCD Cable Pres 0: Connected"
#@---------------------------------------------------
#@ Date : 20130702
#@ Author : Carl R. Friend
#@ Reason : Improving wrong authentication timeout and exit UNKNOWN
#@---------------------------------------------------
#@ Date : 20130725
#@ Author : Phil Randal (phil.randal@gmail.com)
#@ Reason : Fix lookup of warranty info for Dell
#@---------------------------------------------------
#@ Date : 20140319
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Another two workarounds for Dell systems (VGA Cable Pres 0, Add-in Card 4 PEM Presence 0)
#@---------------------------------------------------
#@ Date : 20150109
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Output serial number of chassis if a blade server is checked
#@---------------------------------------------------
#@ Date : 20150119
#@ Author : Andreas Gottwald
#@ Reason : Fix NoneType element bug
#@---------------------------------------------------
#@ Date : 20150626
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Added support for patched pywbem 0.7.0 and new version 0.8.0, handle SSL error exception
#@---------------------------------------------------
#@ Date : 20150710
#@ Author : Stanislav German-Evtushenko
#@ Reason : Exit Unknown instead of Critical for timeouts and auth errors
#@---------------------------------------------------
#@ Date : 20151111
#@ Author : Stefan Roos
#@ Reason : Removed unused sensor_value variable and string import.
#@ Reason : Added global hosturl variable declaration after imports.
#@---------------------------------------------------
#@ Date : 20160411
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Distinguish between pywbem 0.7 and 0.8 (which is now released)
#@---------------------------------------------------
#@ Date : 20160531
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Add parameter for variable CIM port (useful when behind NAT)
#@---------------------------------------------------
#@ Date : 20161013
#@ Author : Claudio Kuenzler (www.claudiokuenzler.com)
#@ Reason : Added support for pywbem 0.9.x (and upcoming releases)
#@---------------------------------------------------
import sys
import time
import pywbem
import re
import pkg_resources
from optparse import OptionParser,OptionGroup
version = '20161013'
NS = 'root/cimv2'
hosturl = ''
# define classes to check 'OperationStatus' instance
ClassesToCheck = [
'OMC_SMASHFirmwareIdentity',
'CIM_Chassis',
'CIM_Card',
'CIM_ComputerSystem',
'CIM_NumericSensor',
'CIM_Memory',
'CIM_Processor',
'CIM_RecordLog',
'OMC_DiscreteSensor',
'OMC_Fan',
'OMC_PowerSupply',
'VMware_StorageExtent',
'VMware_Controller',
'VMware_StorageVolume',
'VMware_Battery',
'VMware_SASSATAPort'
]
sensor_Type = {
0:'unknown',
1:'Other',
2:'Temperature',
3:'Voltage',
4:'Current',
5:'Tachometer',
6:'Counter',
7:'Switch',
8:'Lock',
9:'Humidity',
10:'Smoke Detection',
11:'Presence',
12:'Air Flow',
13:'Power Consumption',
14:'Power Production',
15:'Pressure',
16:'Intrusion',
32768:'DMTF Reserved',
65535:'Vendor Reserved'
}
data = []
perf_Prefix = {
1:'Pow',
2:'Vol',
3:'Cur',
4:'Tem',
5:'Fan',
6:'FanP'
}
# parameters
# host name
hostname=''
# cim port
cimport=''
# user
user=''
# password
password=''
# vendor - possible values are 'unknown', 'auto', 'dell', 'hp', 'ibm', 'intel'
vendor='unknown'
# verbose
verbose=False
# Produce performance data output for nagios
perfdata=False
# timeout
timeout = 0
# elements to ignore (full SEL, broken BIOS, etc)
ignore_list=[]
# urlise model and tag numbers (currently only Dell supported, but the code does the right thing for other vendors)
urlise_country=''
# collect perfdata for each category
get_power = True
get_volts = True
get_current = True
get_temp = True
get_fan = True
# define exit codes
ExitOK = 0
ExitWarning = 1
ExitCritical = 2
ExitUnknown = 3
# Special handling for blade servers
isblade = "no"
def dell_country(country):
if country == 'at': # Austria
return 'at/de/'
if country == 'be': # Belgium
return 'be/nl/'
if country == 'cz': # Czech Republic
return 'cz/cs/'
if country == 'de': # Germany
return 'de/de/'
if country == 'dk': # Denmark
return 'dk/da/'
if country == 'es': # Spain
return 'es/es/'
if country == 'fi': # Finland
return 'fi/fi/'
if country == 'fr': # France
return 'fr/fr/'
if country == 'gr': # Greece
return 'gr/en/'
if country == 'it': # Italy
return 'it/it/'
if country == 'il': # Israel
return 'il/en/'
if country == 'me': # Middle East
return 'me/en/'
if country == 'no': # Norway
return 'no/no/'
if country == 'nl': # The Netherlands
return 'nl/nl/'
if country == 'pl': # Poland
return 'pl/pl/'
if country == 'pt': # Portugal
return 'pt/en/'
if country == 'ru': # Russia
return 'ru/ru/'
if country == 'se': # Sweden
return 'se/sv/'
if country == 'uk': # United Kingdom
return 'uk/en/'
if country == 'za': # South Africa
return 'za/en/'
if country == 'br': # Brazil
return 'br/pt/'
if country == 'ca': # Canada
return 'ca/en/'
if country == 'mx': # Mexico
return 'mx/es/'
if country == 'us': # United States
return 'us/en/'
if country == 'au': # Australia
return 'au/en/'
if country == 'cn': # China
return 'cn/zh/'
if country == 'in': # India
return 'in/en/'
# default
return 'en/us/'
def urlised_server_info(vendor, country, server_info):
#server_inf = server_info
if vendor == 'dell' :
# Dell support URLs (idea and tables borrowed from check_openmanage)
du = 'http://www.dell.com/support/troubleshooting/' + dell_country(country) + '19/Product/poweredge-'
if (server_info is not None) :
p=re.match('(.*)PowerEdge (.*) (.*)',server_info)
if (p is not None) :
md=p.group(2)
if md == 'R210 II':
md='r210-2'
md=md.lower()
server_info = p.group(1) + 'PowerEdge ' + p.group(2)+' ' + p.group(3)
elif vendor == 'hp':
return server_info
elif vendor == 'ibm':
return server_info
elif vendor == 'intel':
return server_info
return server_info
# ----------------------------------------------------------------------
def system_tag_url(vendor,country):
if vendor == 'dell':
# Dell support sites
supportsite = 'http://www.dell.com/support/troubleshooting/'
dellsuffix = 'nodhs1/Index?t=warranty&servicetag='
# warranty URLs for different country codes
return supportsite + dell_country(country) + dellsuffix
# elif vendor == 'hp':
# elif vendor == 'ibm':
# elif vendor == 'intel':
return ''
# ----------------------------------------------------------------------
def urlised_serialnumber(vendor,country,SerialNumber):
if SerialNumber is not None :
tu = system_tag_url(vendor,country)
if tu != '' :
SerialNumber = '' + SerialNumber + ''
return SerialNumber
# ----------------------------------------------------------------------
def verboseoutput(message) :
if verbose:
print "%s %s" % (time.strftime("%Y%m%d %H:%M:%S"), message)
# ----------------------------------------------------------------------
def getopts() :
global hosturl,cimport,user,password,vendor,verbose,perfdata,urlise_country,timeout,ignore_list,get_power,get_volts,get_current,get_temp,get_fan
usage = "usage: %prog -H hostname -U username -P password [-C port -V system -v -p -I XX]\n" \
"example: %prog -H my-shiny-new-vmware-server -U root -P fakepassword -C 5989 -V auto -I uk\n\n" \
"or, verbosely:\n\n" \
"usage: %prog --host=hostname --user=username --pass=password [--cimport=port --vendor=system --verbose --perfdata --html=XX]\n"
parser = OptionParser(usage=usage, version="%prog "+version)
group1 = OptionGroup(parser, 'Mandatory parameters')
group2 = OptionGroup(parser, 'Optional parameters')
group1.add_option("-H", "--host", dest="host", help="report on HOST", metavar="HOST")
group1.add_option("-U", "--user", dest="user", help="user to connect as", metavar="USER")
group1.add_option("-P", "--pass", dest="password", \
help="password, if password matches file:, first line of given file will be used as password", metavar="PASS")
group2.add_option("-C", "--cimport", dest="cimport", help="CIM port (default 5989)", metavar="CIMPORT")
group2.add_option("-V", "--vendor", dest="vendor", help="Vendor code: auto, dell, hp, ibm, intel, or unknown (default)", \
metavar="VENDOR", type='choice', choices=['auto','dell','hp','ibm','intel','unknown'],default="unknown")
group2.add_option("-v", "--verbose", action="store_true", dest="verbose", default=False, \
help="print status messages to stdout (default is to be quiet)")
group2.add_option("-p", "--perfdata", action="store_true", dest="perfdata", default=False, \
help="collect performance data for pnp4nagios (default is not to)")
group2.add_option("-I", "--html", dest="urlise_country", default="", \
help="generate html links for country XX (default is not to)", metavar="XX")
group2.add_option("-t", "--timeout", action="store", type="int", dest="timeout", default=0, \
help="timeout in seconds - no effect on Windows (default = no timeout)")
group2.add_option("-i", "--ignore", action="store", type="string", dest="ignore", default="", \
help="comma-separated list of elements to ignore")
group2.add_option("--no-power", action="store_false", dest="get_power", default=True, \
help="don't collect power performance data")
group2.add_option("--no-volts", action="store_false", dest="get_volts", default=True, \
help="don't collect voltage performance data")
group2.add_option("--no-current", action="store_false", dest="get_current", default=True, \
help="don't collect current performance data")
group2.add_option("--no-temp", action="store_false", dest="get_temp", default=True, \
help="don't collect temperature performance data")
group2.add_option("--no-fan", action="store_false", dest="get_fan", default=True, \
help="don't collect fan performance data")
parser.add_option_group(group1)
parser.add_option_group(group2)
# check input arguments
if len(sys.argv) < 2:
print "no parameters specified\n"
parser.print_help()
sys.exit(-1)
# if first argument starts with 'https://' we have old-style parameters, so handle in old way
if re.match("https://",sys.argv[1]):
# check input arguments
if len(sys.argv) < 5:
print "too few parameters\n"
parser.print_help()
sys.exit(-1)
if len(sys.argv) > 5 :
if sys.argv[5] == "verbose" :
verbose = True
hosturl = sys.argv[1]
user = sys.argv[2]
password = sys.argv[3]
vendor = sys.argv[4]
else:
# we're dealing with new-style parameters, so go get them!
(options, args) = parser.parse_args()
# Making sure all mandatory options appeared.
mandatories = ['host', 'user', 'password']
for m in mandatories:
if not options.__dict__[m]:
print "mandatory parameter '--" + m + "' is missing\n"
parser.print_help()
sys.exit(-1)
hostname=options.host.lower()
# if user has put "https://" in front of hostname out of habit, do the right thing
# hosturl will end up as https://hostname
if re.match('^https://',hostname):
hosturl = hostname
else:
hosturl = 'https://' + hostname
user=options.user
password=options.password
cimport=options.cimport
vendor=options.vendor.lower()
verbose=options.verbose
perfdata=options.perfdata
urlise_country=options.urlise_country.lower()
timeout=options.timeout
ignore_list=options.ignore.split(',')
get_power=options.get_power
get_volts=options.get_volts
get_current=options.get_current
get_temp=options.get_temp
get_fan=options.get_fan
# if user or password starts with 'file:', use the first string in file as user, second as password
if (re.match('^file:', user) or re.match('^file:', password)):
if re.match('^file:', user):
filextract = re.sub('^file:', '', user)
filename = open(filextract, 'r')
filetext = filename.readline().split()
user = filetext[0]
password = filetext[1]
filename.close()
elif re.match('^file:', password):
filextract = re.sub('^file:', '', password)
filename = open(filextract, 'r')
filetext = filename.readline().split()
password = filetext[0]
filename.close()
# ----------------------------------------------------------------------
getopts()
# if running on Windows, don't use timeouts and signal.alarm
on_windows = True
os_platform = sys.platform
if os_platform != "win32":
on_windows = False
import signal
def handler(signum, frame):
print 'UNKNOWN: Execution time too long!'
sys.exit(ExitUnknown)
if cimport:
verboseoutput("Using manually defined CIM port "+cimport)
hosturl += ':'+cimport
# connection to host
verboseoutput("Connection to "+hosturl)
# pywbem 0.7.0 handling is special, some patched 0.7.0 installations work differently
pywbemversion = pkg_resources.get_distribution("pywbem").version
verboseoutput("Found pywbem version "+pywbemversion)
if '0.7.' in pywbemversion:
try:
conntest = pywbem.WBEMConnection(hosturl, (user,password))
c = conntest.EnumerateInstances('CIM_Card')
except:
#raise
verboseoutput("Connection error, disable SSL certification verification (probably patched pywbem)")
wbemclient = pywbem.WBEMConnection(hosturl, (user,password), no_verification=True)
else:
verboseoutput("Connection worked")
wbemclient = pywbem.WBEMConnection(hosturl, (user,password))
# pywbem 0.8.0 and later
else:
wbemclient = pywbem.WBEMConnection(hosturl, (user,password), NS, no_verification=True)
# Add a timeout for the script. When using with Nagios, the Nagios timeout cannot be < than plugin timeout.
if on_windows == False and timeout > 0:
signal.signal(signal.SIGALRM, handler)
signal.alarm(timeout)
# run the check for each defined class
GlobalStatus = ExitUnknown
server_info = ""
bios_info = ""
SerialNumber = ""
ExitMsg = ""
# if vendor is specified as 'auto', try to get vendor from CIM
# note: the default vendor is 'unknown'
if vendor=='auto':
try:
c=wbemclient.EnumerateInstances('CIM_Chassis')
except pywbem.cim_operations.CIMError,args:
if ( args[1].find('Socket error') >= 0 ):
print "UNKNOWN: %s" %args
sys.exit (ExitUnknown)
else:
verboseoutput("Unknown CIM Error: %s" % args)
except pywbem.cim_http.AuthError,arg:
verboseoutput("Global exit set to UNKNOWN")
GlobalStatus = ExitUnknown
print "UNKNOWN: Authentication Error"
sys.exit (GlobalStatus)
else:
man=c[0][u'Manufacturer']
if re.match("Dell",man):
vendor="dell"
elif re.match("HP",man):
vendor="hp"
elif re.match("IBM",man):
vendor="ibm"
elif re.match("Intel",man):
vendor="intel"
else:
vendor='unknown'
for classe in ClassesToCheck :
verboseoutput("Check classe "+classe)
try:
instance_list = wbemclient.EnumerateInstances(classe)
except pywbem.cim_operations.CIMError,args:
if ( args[1].find('Socket error') >= 0 ):
print "UNKNOWN: %s" %args
sys.exit (ExitUnknown)
else:
verboseoutput("Unknown CIM Error: %s" % args)
except pywbem.cim_http.AuthError,arg:
verboseoutput("Global exit set to UNKNOWN")
GlobalStatus = ExitUnknown
print "UNKNOWN: Authentication Error"
sys.exit (GlobalStatus)
else:
# GlobalStatus = ExitOK #ARR
for instance in instance_list :
elementName = instance['ElementName']
if elementName is None :
elementName = 'Unknown'
elementNameValue = elementName
verboseoutput(" Element Name = "+elementName)
# Ignore element if we don't want it
if elementName in ignore_list :
verboseoutput(" (ignored)")
continue
# BIOS & Server info
if elementName == 'System BIOS' :
bios_info = instance[u'Name'] + ': ' \
+ instance[u'VersionString'] + ' ' \
+ str(instance[u'ReleaseDate'].datetime.date())
verboseoutput(" VersionString = "+instance[u'VersionString'])
elif elementName == 'Chassis' :
man = instance[u'Manufacturer']
if man is None :
man = 'Unknown Manufacturer'
verboseoutput(" Manufacturer = "+man)
SerialNumber = instance[u'SerialNumber']
SerialChassis = instance[u'SerialNumber']
if SerialNumber:
verboseoutput(" SerialNumber = "+SerialNumber)
server_info = man + ' '
if vendor != 'intel':
model = instance[u'Model']
if model:
verboseoutput(" Model = "+model)
server_info += model + ' s/n:'
elif elementName == 'Server Blade' :
SerialNumber = instance[u'SerialNumber']
if SerialNumber:
verboseoutput(" SerialNumber = "+SerialNumber)
isblade = "yes"
# Report detail of Numeric Sensors and generate nagios perfdata
if classe == "CIM_NumericSensor" :
sensorType = instance[u'sensorType']
sensStr = sensor_Type.get(sensorType,"Unknown")
if sensorType:
verboseoutput(" sensorType = %d - %s" % (sensorType,sensStr))
units = instance[u'BaseUnits']
if units:
verboseoutput(" BaseUnits = %d" % units)
# grab some of these values for Nagios performance data
scale = 10**instance[u'UnitModifier']
verboseoutput(" Scaled by = %f " % scale)
cr = int(instance[u'CurrentReading'])*scale
verboseoutput(" Current Reading = %f" % cr)
elementNameValue = "%s: %g" % (elementName,cr)
ltnc = 0
utnc = 0
ltc = 0
utc = 0
if instance[u'LowerThresholdNonCritical'] is not None:
ltnc = instance[u'LowerThresholdNonCritical']*scale
verboseoutput(" Lower Threshold Non Critical = %f" % ltnc)
if instance[u'UpperThresholdNonCritical'] is not None:
utnc = instance[u'UpperThresholdNonCritical']*scale
verboseoutput(" Upper Threshold Non Critical = %f" % utnc)
if instance[u'LowerThresholdCritical'] is not None:
ltc = instance[u'LowerThresholdCritical']*scale
verboseoutput(" Lower Threshold Critical = %f" % ltc)
if instance[u'UpperThresholdCritical'] is not None:
utc = instance[u'UpperThresholdCritical']*scale
verboseoutput(" Upper Threshold Critical = %f" % utc)
#
if perfdata:
perf_el = elementName.replace(' ','_')
# Power and Current
if sensorType == 4: # Current or Power Consumption
if units == 7: # Watts
if get_power:
data.append( ("%s=%g;%g;%g " % (perf_el, cr, utnc, utc),1) )
elif units == 6: # Current
if get_current:
data.append( ("%s=%g;%g;%g " % (perf_el, cr, utnc, utc),3) )
# PSU Voltage
elif sensorType == 3: # Voltage
if get_volts:
data.append( ("%s=%g;%g;%g " % (perf_el, cr, utnc, utc),2) )
# Temperatures
elif sensorType == 2: # Temperature
if get_temp:
data.append( ("%s=%g;%g;%g " % (perf_el, cr, utnc, utc),4) )
# Fan speeds
elif sensorType == 5: # Tachometer
if get_fan:
if units == 65: # percentage
data.append( ("%s=%g%%;%g;%g " % (perf_el, cr, utnc, utc),6) )
else:
data.append( ("%s=%g;%g;%g " % (perf_el, cr, utnc, utc),5) )
elif classe == "CIM_Processor" :
verboseoutput(" Family = %d" % instance['Family'])
verboseoutput(" CurrentClockSpeed = %dMHz" % instance['CurrentClockSpeed'])
# HP Check
if vendor == "hp" :
if instance['HealthState'] is not None :
elementStatus = instance['HealthState']
verboseoutput(" Element HealthState = %d" % elementStatus)
interpretStatus = {
0 : ExitOK, # Unknown
5 : ExitOK, # OK
10 : ExitWarning, # Degraded
15 : ExitWarning, # Minor
20 : ExitCritical, # Major
25 : ExitCritical, # Critical
30 : ExitCritical, # Non-recoverable Error
}[elementStatus]
if (interpretStatus == ExitCritical) :
verboseoutput("GLobal exit set to CRITICAL")
GlobalStatus = ExitCritical
ExitMsg += " CRITICAL : %s " % elementNameValue
if (interpretStatus == ExitWarning and GlobalStatus != ExitCritical) :
verboseoutput("GLobal exit set to WARNING")
GlobalStatus = ExitWarning
ExitMsg += " WARNING : %s " % elementNameValue
# Added the following for when GlobalStatus is ExitCritical and a warning is detected
# This way the ExitMsg gets added but GlobalStatus isn't changed
if (interpretStatus == ExitWarning and GlobalStatus == ExitCritical) : # ARR
ExitMsg += " WARNING : %s " % elementNameValue #ARR
# Added the following so that GlobalStatus gets set to OK if there's no warning or critical
if (interpretStatus == ExitOK and GlobalStatus != ExitWarning and GlobalStatus != ExitCritical) : #ARR
GlobalStatus = ExitOK #ARR
# Dell, Intel, IBM and unknown hardware check
elif (vendor == "dell" or vendor == "intel" or vendor == "ibm" or vendor=="unknown") :
# Added 20121027 As long as Dell doesnt correct these CIM elements return code we have to ignore it
ignore_list.append("System Board 1 Riser Config Err 0: Connected")
ignore_list.append("System Board 1 LCD Cable Pres 0: Connected")
ignore_list.append("System Board 1 VGA Cable Pres 0: Connected")
ignore_list.append("Add-in Card 4 PEM Presence 0: Connected")
if instance['OperationalStatus'] is not None :
elementStatus = instance['OperationalStatus'][0]
verboseoutput(" Element Op Status = %d" % elementStatus)
interpretStatus = {
0 : ExitOK, # Unknown
1 : ExitCritical, # Other
2 : ExitOK, # OK
3 : ExitWarning, # Degraded
4 : ExitWarning, # Stressed
5 : ExitWarning, # Predictive Failure
6 : ExitCritical, # Error
7 : ExitCritical, # Non-Recoverable Error
8 : ExitWarning, # Starting
9 : ExitWarning, # Stopping
10 : ExitCritical, # Stopped
11 : ExitOK, # In Service
12 : ExitWarning, # No Contact
13 : ExitCritical, # Lost Communication
14 : ExitCritical, # Aborted
15 : ExitOK, # Dormant
16 : ExitCritical, # Supporting Entity in Error
17 : ExitOK, # Completed
18 : ExitOK, # Power Mode
19 : ExitOK, # DMTF Reserved
20 : ExitOK # Vendor Reserved
}[elementStatus]
if (interpretStatus == ExitCritical) :
verboseoutput("Global exit set to CRITICAL")
GlobalStatus = ExitCritical
ExitMsg += " CRITICAL : %s " % elementNameValue
if (interpretStatus == ExitWarning and GlobalStatus != ExitCritical) :
verboseoutput("GLobal exit set to WARNING")
GlobalStatus = ExitWarning
ExitMsg += " WARNING : %s " % elementNameValue
# Added same logic as in 20100702 here, otherwise Dell servers would return UNKNOWN instead of OK
if (interpretStatus == ExitWarning and GlobalStatus == ExitCritical) : # ARR
ExitMsg += " WARNING : %s " % elementNameValue #ARR
if (interpretStatus == ExitOK and GlobalStatus != ExitWarning and GlobalStatus != ExitCritical) : #ARR
GlobalStatus = ExitOK #ARR
if elementName == 'Server Blade' :
if SerialNumber :
if SerialNumber.find(".") != -1 :
SerialNumber = SerialNumber.split('.')[1]
# Munge the ouptput to give links to documentation and warranty info
if (urlise_country != '') :
SerialNumber = urlised_serialnumber(vendor,urlise_country,SerialNumber)
server_info = urlised_server_info(vendor,urlise_country,server_info)
# If this is a blade server, also output chassis serial number as additional info
if (isblade == "yes") :
SerialNumber += " Chassis S/N: %s " % (SerialChassis)
# Output performance data
perf = '|'
if perfdata:
sdata=[]
ctr=[0,0,0,0,0,0,0]
# sort the data so we always get perfdata in the right order
# we make no assumptions about the order in which CIM returns data
# first sort by element name (effectively) and insert sequence numbers
for p in sorted(data):
p1 = p[1]
sdata.append( ("P%d%s_%d_%s") % (p1,perf_Prefix[p1], ctr[p1], p[0]) )
ctr[p1] += 1
# then sort perfdata into groups and output perfdata string
for p in sorted(sdata):
perf += p
# sanitise perfdata - don't output "|" if nothing to report
if perf == '|':
perf = ''
if GlobalStatus == ExitOK :
print "OK - Server: %s %s %s%s" % (server_info, SerialNumber, bios_info, perf)
elif GlobalStatus == ExitUnknown :
print "UNKNOWN: %s" % (ExitMsg) #ARR
else:
print "%s- Server: %s %s %s%s" % (ExitMsg, server_info, SerialNumber, bios_info, perf)